PS-6100

The PS-6100 is part of our General Purpose SLA range. This 6.0V and 11.2Ah battery provides dependable power for general purpose and standby uses. Features include AGM Technology, Gas Recombination, Power Volume Ratio, SLA ABS Case, and SLA Maintenance Free. These batteries are commonly used in Emergency Lighting, Fire Security, General Purpose, Medical, Signaling (Air,Rail,Sea), Solar, Telecomm, UPS, Utility, and Wind requiring reliable, light cyclic backup power. Backed by decades of expertise, Power-Sonic batteries are subject to stringent quality controls through each step of the manufacturing process to ensure compliance, performance consistency, and reliability.
Request A QuoteGet Datasheet
Product Group Marketing Paragraph
Versatile sealed lead acid batteries specifically engineered for use in general purpose float and light cyclic applications including fire and security systems, emergency lighting, UPS, toys and medical devices.
Long Term Storage Statement
PS series batteries may be stored for up to 6 months at 25C (77 F) and then a freshening charge is required. For higher temperatures the time interval will be shorter

Operating Temperature
Range _ Charge:
4°F - 104°F
(20°C)
(40°C)
Operating Temperature
Range _ Discharge:
5°F - 122°F
(15°C)
(50°C)
Operating Temperature
Range _ Recommended:
5°F - 104°F
(15°C)
(40°C)
Dimensional Tolerances:
+/- 0.08 in. (+/- 2mm) for length, width, and height dimensions
Additional Specifications:
For the detailed technical specifications please refer to the model's technical document
Group Description:

Featuring a spill-proof VRLA design and dependable performance, these batteries come in a broad range of sizes and are trusted for security systems, medical devices, and emergency lighting.

Product Description:

The PS-6100 is part of our General Purpose SLA range. This 6.0V and 11.2Ah battery provides dependable power for general purpose and standby uses. Features include AGM Technology, Gas Recombination, Power Volume Ratio, SLA ABS Case, and SLA Maintenance Free. These batteries are commonly used in Emergency Lighting, Fire Security, General Purpose, Medical, Signaling (Air,Rail,Sea), Solar, Telecomm, UPS, Utility, and Wind requiring reliable, light cyclic backup power. Backed by decades of expertise, Power-Sonic batteries are subject to stringent quality controls through each step of the manufacturing process to ensure compliance, performance consistency, and reliability.

Charging Description:

Cycle Applications: Apply constant voltage charge at 2.35VPC – 2.45VPC (14.1 to 14.7 volts for 12V Monobloc) at 20°C. The initial charging current should be set at less than C/5 Amps. Switch to float charge when the current falls to a 3% capacity rate to avoid overcharging. Stand-By or "Float" Service: Apply constant voltage charge of 2.25VPC – 2.30VPC (13.5 to 13.8 volts for 12V Monobloc) at 20°C. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Temperature Compensation: Charging voltage for both cyclic and stand-by applications should be regulated in relation to ambient temperature. As temperature rises, charging voltage should be reduced to prevent overcharge and increased as the temperature falls to avoid undercharge. For further charging information, including temperature compensation factors, see the Power-Sonic Technical Manual.

Expand
Voltage 6.0
Number of Series Cells 3.0
Stored Energy (Wh) 72.0
Rated Capacity 20hr 12.0
Rated Capacity 10hr 11.2
Rated Capacity 5hr 10.35
Rated Capacity 1hr 7.2
Capacity Voltage 20hr 5.25
Capacity Voltage 10hr 5.25
Capacity Current 10hr 1.12
Capacity Voltage 5hr 5.1
Capacity Voltage 1hr 4.8
Cycle Constant Voltage Range 7.05V-7.20V-15mV/℃
Float Constant Voltage Range 6.75V-6.90V-9mV/℃
Initial Charging Current (A) 3.6
Capacity Current 5hr 2.07
Capacity Current 1hr 7.2
Max Continuous Discharge Current (A) 120.0
Internal Resistance (mΩ) 12.0
Capacity Current 20hr 0.6
Short Circuit Current (A) 336.0
Recommended Chargers PSC-61000ACX

Constant Current Discharge Table:
VoltageOverTime5min10min15min20min30min45min1h1.5h2h3h4h5h6h8h10h20h
1.60V/cell43.728.621.617.112.38.887.25.224.123.132.52.121.811.421.160.618
1.65V/cell40.627.220.816.512.18.737.15.164.073.092.462.091.791.411.150.613
1.67V/cell40.226.920.616.412.08.657.035.114.043.072.452.081.781.41.140.609
1.70V/cell38.626.220.216.211.88.556.965.064.013.042.432.071.771.391.130.606
1.75V/cell35.925.119.515.711.58.396.844.983.943.02.42.041.741.371.120.6
1.80V/cell33.223.918.815.211.38.236.724.93.882.952.372.011.721.351.10.594
1.85V/cell30.622.718.114.811.08.076.594.813.822.912.341.991.71.341.090.587
Expand
Constant Power Discharge Table:
VoltageOverTime5min10min15min20min30min45min1h1.5h2h3h4h5h6h8h10h20h
1.60V/cell80.453.140.432.123.316.913.810.07.976.084.884.153.562.82.291.24
1.65V/cell75.351.039.231.323.016.713.69.97.896.014.824.113.522.782.271.23
1.67V/cell74.650.538.931.122.816.613.59.877.845.984.84.093.52.762.261.22
1.70V/cell71.849.338.230.722.516.413.49.797.785.944.774.063.482.742.241.21
1.75V/cell67.347.437.129.922.116.213.29.667.685.874.724.023.442.712.221.2
1.80V/cell62.745.436.029.221.715.913.09.537.585.794.663.973.42.682.191.19
1.85V/cell58.243.534.828.421.215.712.89.47.495.724.63.923.362.652.171.17
Expand

Charge Voltage (25C) - Cycle Use : 2.35V-2.40V/cell -5mV/cell/℃

Charge Voltage (25C) - Float Charge : 2.25V-2.30V/cell -3mV/cell/℃

Recommended Charge Current (C rate) : 0.1C-0.3C

Image Featured
PS-6100
Case Material ABS (UL94 HB or V-0 optional)
Minimum Weight (kg) 1.6
Minimum Weight (lbs) 3.53
Length (in) 5.94
Length (mm) 151.0
Width (in) 1.97
Dimensions Image
PS-6100
Width (mm) 50.0
Height (in) 3.7
Height (mm) 94.0
Height Over Terminal (in) 3.94
Height Over Terminal (mm) 100.0

CE
CE

CE marking confirms a product meets EU safety, health, and environmental protection standards for battery and energy systems.

Conflict Minerals

Conflict-free mineral certification ensuring ethical sourcing and transparent supply chain for responsible production.

Extended Minerals

Extended mineral reporting meets global supply chain transparency standards for responsible and ethical sourcing practices.

IEC60896
IEC60896

IEC 60896 standard ensures stationary lead-acid batteries meet safety, performance, and float charge application requirements.

ISO9001:2015
ISO9001:2015

ISO 9001:2015 certification ensures consistent quality management and manufacturing standards for energy storage products.

PFAS

PFAS-free certification verifying environmentally responsible manufacturing of batteries and energy storage technologies.

Prop65
Prop65

California Proposition 65 compliant, providing consumer safety through reduced chemical exposure in battery manufacturing.

REACH

REACH compliant with EU chemical safety standards ensuring restricted substances are controlled in all battery components.

RoHS

RoHS compliance ensures restriction of hazardous substances in electrical, electronic, and battery-powered products.

SLA Transport
SLA Transport

Sealed lead-acid batteries classified UN2800 non-spillable, certified safe for air, sea, and ground transport worldwide.

SVHC

SVHC compliant with EU REACH regulations for Substances of Very High Concern used in electrical and energy storage products.

TSCA

U.S. EPA TSCA compliance ensures toxic substances are regulated for safe manufacturing of batteries and electronic components.

UL 1989

UL 1989 certified for valve-regulated and vented lead-acid batteries used in UPS, emergency, and backup power applications.

VdS
VdS

VdS certified for tested reliability, quality, and safety of batteries in alarm, security, and backup power systems.

Characteristic 0601002602 0601002671 0601003402 S0601002809010 S0601002909010
Terminal Type F1 F1 F2 F1 F1
VdS n n n y n
Active on Web US y y y y n
Active on Web EMEA y y y y n
Terminal Image 0601002602 0601003402 S0601002809010 S0601002909010
SKU Battery PS-6100 F1 PS-6100 F1 PS-6100 F2 PS-6100 F1 VDS PS-6100 F1
  • PS-6100 F1
  • PS-6100 F1
  • PS-6100 F2
  • PS-6100 F1 VDS
  • PS-6100 F1

Features and Documents

AGM Technology

Absorbent Glass Mat (AGM) technology for superior performance, service life, and reliability

Gas Recombination

Gas recombination technology for quick recovery of capacity during charge

Power Volume Ratio

Excellent power to volume ratio yielding high energy density

SLA ABS Case

Rugged vibration and impact resistant ABS case and cover

SLA Maintenance Free

Proven valve regulated technology that guarantees safe operation without maintenance or refilling

Graphs

Capacity Retention SLA

Capacity Retention SLA

Shelf life of SLA at various temperatures

PS Cycle Life

PS Cycle Life

Cycle life vs depth of discharge for the PS series

SLA Charging

SLA Charging

Charging characteristics for SLA

SLA Float Life 5YR

SLA Float Life 5YR

5 year float life vs. temperature for SLA

Join Us in Powering the Future

Interested in Our Products?

Speak with our experts to find the best batteries, chargers, or
energy storage solutions for your specific application.

FAQs About Battery and
Energy Solutions

Find answers to the most common questions about our energy solutions, including compliance, customization, and delivery options.

Yes, our batteries are engineered for universal fit with most major OEM fire, security, and access control panels for easy installation.

y delivering dependable backup and energy storage solutions, our products support continuous operation for critical automation, helping prevent downtime caused by power loss or disruptions.

Most Power-Sonic industrial batteries are maintenance-free, minimizing routine service while maximizing uptime and reducing total cost of ownership for busy operations.