PHR-1290

The PHR-1290 FR is part of our High-Rate Discharge range. This 12.0V and 20.7Ah battery provides high-density rapid power. Features include Dual Paste, High-Rate UPS Application, Plate Pasting, SLA ABS Case, and SLA Maintenance Free. These batteries are commonly used in Backup Power Systems, Edge Data Center, Telecomm, and UPS requiring short-duration high-current discharge. Backed by decades of expertise, Power-Sonic batteries are subject to stringent quality controls through each step of the manufacturing process to ensure compliance, performance consistency, and reliability.
Request A QuoteGet Datasheet
Product Group Marketing Paragraph
High-rate batteries deliver quick bursts of power with low internal resistance and excellent power density, making them ideal for UPS systems, data centers, and emergency backup where reliable high-current performance is essential.
Long Term Storage Statement
PHR series batteries may be stored for up to 6 months at 25C (77 F) and then a freshening charge is required. For higher temperatures the time interval will be shorter

Operating Temperature
Range _ Charge:
4°F - 104°F
(-20°C)
(40°C)
Operating Temperature
Range _ Discharge:
4°F - 131°F
(-20°C)
(55°C)
Operating Temperature
Range _ Recommended:
5°F - 122°F
(-15°C)
(50°C)
Dimensional Tolerances:
+/- 0.08 in. (+/- 2mm) for length, width, and height dimensions
Additional Specifications:
For the detailed technical specifications please refer to the model's technical document
Group Description:

Optimized for short-duration, high-current discharge, these batteries deliver excellent power density, reliable valve regulation, and dependable performance.

Product Description:

The PHR-1290 FR is part of our High-Rate Discharge range. This 12.0V and 20.7Ah battery provides high-density rapid power. Features include Dual Paste, High-Rate UPS Application, Plate Pasting, SLA ABS Case, and SLA Maintenance Free. These batteries are commonly used in Backup Power Systems, Edge Data Center, Telecomm, and UPS requiring short-duration high-current discharge. Backed by decades of expertise, Power-Sonic batteries are subject to stringent quality controls through each step of the manufacturing process to ensure compliance, performance consistency, and reliability.

Charging Description:

Cycle Applications: Apply constant voltage charge at 2.35VPC – 2.45VPC (14.1 to 14.7 volts for 12V Monobloc) at 20°C. The initial charging current should be set at less than C/5 Amps. Switch to float charge when the current falls to a 3% capacity rate to avoid overcharging. Stand-By or "Float" Service: Apply constant voltage charge of 2.25VPC – 2.30VPC (13.5 to 13.8 volts for 12V Monobloc) at 20°C. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Temperature Compensation: Charging voltage for both cyclic and stand-by applications should be regulated in relation to ambient temperature. As temperature rises, charging voltage should be reduced to prevent overcharge and increased as the temperature falls to avoid undercharge. For further charging information, including temperature compensation factors, see the Power-Sonic Technical Manual.

Expand
Voltage 12.0
Number of Series Cells 6.0
Stored Energy (Wh) 264.0
Rated Capacity 20hr 22.0
Rated Capacity 10hr 20.7
Rated Capacity 5hr 18.25
Rated Capacity 1hr 14.6
Capacity Voltage 20hr 10.5
Capacity Voltage 10hr 10.5
Capacity Current 10hr 2.07
Capacity Voltage 5hr 10.2
Capacity Voltage 1hr 9.6
Cycle Constant Voltage Range 14.00V – 14.70V
Float Constant Voltage Range 13.50V-13.80V-18mV/℃
Initial Charging Current (A) 5.5
Capacity Current 5hr 3.65
Capacity Current 1hr 14.6
Max Continuous Discharge Current (A) 470.0
Internal Resistance (mΩ) 7.0
Capacity Current 20hr 1.1
Short Circuit Current (A) 616.0
Nominal Power W/Cell 15 min 93.3
Recommended Chargers PSC-122000ACX
Nominal Power W/Cell 15min Voltage 10.0
Charge Voltage (25C) - Equalization Charge 2.30V-2.40V/cell -4mV/cell/℃

Constant Current Discharge Table:
VoltageOverTime5min10min15min20min30min45min1h1.5h2h3h4h5h6h8h10h20h
1.60V/cell101.565.848.237.727.418.614.610.48.295.764.533.763.22.512.151.13
1.65V/cell94.162.546.736.626.718.214.410.38.185.684.473.73.162.482.121.12
1.67V/cell93.261.946.336.326.518.114.310.28.135.654.443.693.152.472.111.12
1.70V/cell89.560.445.335.826.217.914.210.18.055.614.413.653.132.462.11.11
1.75V/cell82.156.843.034.225.217.313.99.927.935.524.353.613.092.432.071.1
1.80V/cell74.453.040.732.524.216.613.79.777.85.444.283.573.052.392.051.09
1.85V/cell65.548.237.430.122.615.812.69.337.695.374.233.523.012.362.021.08
Expand
Constant Power Discharge Table:
VoltageOverTime5min10min15min20min30min45min1h1.5h2h3h4h5h6h8h10h20h
1.60V/cell210.0131.593.376.056.037.129.420.115.411.38.847.356.34.954.062.27
1.65V/cell196.5126.290.974.355.236.629.019.715.111.28.757.36.234.914.02.24
1.67V/cell194.6125.090.073.654.736.328.819.615.011.18.77.256.24.893.992.23
1.70V/cell187.5122.288.472.654.036.028.519.414.910.98.637.26.174.853.972.22
1.75V/cell173.0115.684.469.852.234.928.219.214.710.88.537.116.094.83.922.2
1.80V/cell157.9108.680.466.750.233.727.719.014.610.78.437.046.024.743.882.18
1.85V/cell139.999.374.162.047.031.925.618.114.410.58.326.955.964.73.842.16
Expand

Charge Voltage (25C) - Float Charge : 2.25V-2.30V/cell -3mV/cell/℃

Recommended Charge Current (C rate) : 0.1 C-0.25C

Image Featured
PHR-1290
Case Material ABS (UL94 HB or V-0 optional)
Length in (mm) 7.16 (182.0)
Width in (mm) 3.03 (77.0)
Dimensions Image
PHR-1290
Height in (mm) 6.54 (166.0)
Height Over Terminal in (mm) 6.54 (166.0)
Minimum Weight kg (lbs) 6.85 (15.1)

CE
CE

CE marking confirms a product meets EU safety, health, and environmental protection standards for battery and energy systems.

Conflict Minerals

Conflict-free mineral certification ensuring ethical sourcing and transparent supply chain for responsible production.

Extended Minerals

Extended mineral reporting meets global supply chain transparency standards for responsible and ethical sourcing practices.

IEC60896
IEC60896

IEC 60896 standard ensures stationary lead-acid batteries meet safety, performance, and float charge application requirements.

ISO9001:2015
ISO9001:2015

ISO 9001:2015 certification ensures consistent quality management and manufacturing standards for energy storage products.

PFAS

PFAS-free certification verifying environmentally responsible manufacturing of batteries and energy storage technologies.

Prop65
Prop65

California Proposition 65 compliant, providing consumer safety through reduced chemical exposure in battery manufacturing.

REACH

REACH compliant with EU chemical safety standards ensuring restricted substances are controlled in all battery components.

RoHS

RoHS compliance ensures restriction of hazardous substances in electrical, electronic, and battery-powered products.

SLA Transport
SLA Transport

Sealed lead-acid batteries classified UN2800 non-spillable, certified safe for air, sea, and ground transport worldwide.

SVHC

SVHC compliant with EU REACH regulations for Substances of Very High Concern used in electrical and energy storage products.

TSCA

U.S. EPA TSCA compliance ensures toxic substances are regulated for safe manufacturing of batteries and electronic components.

UL 1989

UL 1989 certified for valve-regulated and vented lead-acid batteries used in UPS, emergency, and backup power applications.

Characteristic HR1290 S1202106709002
Terminal Type M6 M6
VdS n n
Active on Web US y y
Active on Web EMEA y y
Terminal Image HR1290 S1202106709002
SKU Battery PHR-1290 FR M6 PHR-1290 FR M6
  • PHR-1290 FR M6
  • PHR-1290 FR M6

Features and Documents

Dual Paste

Patented dual-paste process for enhanced active material bonding with computer guided volumetric electrolyte control for precision filling

High-Rate UPS Application

Superb high-rate discharge characteristics that ensure reliable, on demand performance in UPS applications

Plate Pasting

Precision plate pasting for higher consistency with 100% load testing to ensure uniform capacity

SLA ABS Case

Rugged vibration and impact resistant ABS case and cover

SLA Maintenance Free

Proven valve regulated technology that guarantees safe operation without maintenance or refilling

Graphs

Capacity Retention SLA

Capacity Retention SLA

Shelf life of SLA at various temperatures

PHR Cycle Life

PHR Cycle Life

Cycle life vs depth of discharge for the PHR series

SLA Charging

SLA Charging

Charging characteristics for SLA

SLA Float Life 5YR

SLA Float Life 5YR

5 year float life vs. temperature for SLA

Join Us in Powering the Future

Interested in Our Products?

Speak with our experts to find the best batteries, chargers, or
energy storage solutions for your specific application.

FAQs About Battery and
Energy Solutions

Find answers to the most common questions about our energy solutions, including compliance, customization, and delivery options.

Yes, our batteries are engineered for universal fit with most major OEM fire, security, and access control panels for easy installation.

y delivering dependable backup and energy storage solutions, our products support continuous operation for critical automation, helping prevent downtime caused by power loss or disruptions.

Most Power-Sonic industrial batteries are maintenance-free, minimizing routine service while maximizing uptime and reducing total cost of ownership for busy operations.