PSH-1280

The PSH-1280 FR is part of our High Rate Discharge Batteries range. This 12.0V and 7.92Ah battery provides high rate discharge and dependable performance. Features include AGM Technology, High-Rate UPS Application, Power Volume Ratio, SLA ABS Case, and SLA Maintenance Free. These batteries are commonly used in Edge Data Center, Fire Security, Telecomm, and UPS requiring rapid discharge in standby and light cyclic use. Backed by decades of expertise, Power-Sonic batteries are subject to stringent quality controls through each step of the manufacturing process to ensure compliance, performance consistency, and reliability.
Request A Quote
Product Group Marketing Paragraph
General-purpose high-rate batteries designed for reliable standby and light cyclic use. With quick discharge capability and durable construction, they deliver dependable performance for UPS systems, emergency lighting, security equipment, and other critical backup applications.
Long Term Storage Statement
PSH series batteries may be stored for up to 6 months at 25C (77 F) and then a freshening charge is required. For higher temperatures the time interval will be shorter

Operating Temperature
Range _ Charge:
4°F - 104°F
(20°C)
(40°C)
Operating Temperature
Range _ Discharge:
5°F - 122°F
(15°C)
(50°C)
Operating Temperature
Range _ Recommended:
5°F - 104°F
(15°C)
(40°C)
Dimensional Tolerances:
+/- 0.08 in. (+/- 2mm) for length, width, and height dimensions
Additional Specifications:
For the detailed technical specifications please refer to the model's technical document
Group Description:

PSH series general-purpose high-rate batteries deliver quick discharge and dependable performance for standby and light cyclic applications.

Product Description:

The PSH-1280 FR is part of our High Rate Discharge Batteries range. This 12.0V and 7.92Ah battery provides high rate discharge and dependable performance. Features include AGM Technology, High-Rate UPS Application, Power Volume Ratio, SLA ABS Case, and SLA Maintenance Free. These batteries are commonly used in Edge Data Center, Fire Security, Telecomm, and UPS requiring rapid discharge in standby and light cyclic use. Backed by decades of expertise, Power-Sonic batteries are subject to stringent quality controls through each step of the manufacturing process to ensure compliance, performance consistency, and reliability.

Charging Description:

Cycle Applications: Apply constant voltage charge at 2.35VPC – 2.45VPC (14.1 to 14.7 volts for 12V Monobloc) at 20°C. The initial charging current should be set at less than C/5 Amps. Switch to float charge when the current falls to a 3% capacity rate to avoid overcharging. Stand-By or "Float" Service: Apply constant voltage charge of 2.25VPC – 2.30VPC (13.5 to 13.8 volts for 12V Monobloc) at 20°C. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Temperature Compensation: Charging voltage for both cyclic and stand-by applications should be regulated in relation to ambient temperature. As temperature rises, charging voltage should be reduced to prevent overcharge and increased as the temperature falls to avoid undercharge. For further charging information, including temperature compensation factors, see the Power-Sonic Technical Manual.

Expand
Voltage 12.0
Number of Series Cells 6.0
Stored Energy (Wh) 102.0
Rated Capacity 20hr 8.5
Rated Capacity 10hr 7.92
Rated Capacity 5hr 7.4
Rated Capacity 1hr 5.92
Capacity Voltage 20hr 10.5
Capacity Voltage 10hr 10.5
Capacity Current 10hr 0.792
Capacity Voltage 5hr 10.2
Capacity Voltage 1hr 9.6
Cycle Constant Voltage Range 14.10V-14.40V-30mV/℃
Float Constant Voltage Range 13.50V-13.80V-18mV/℃
Initial Charging Current (A) 2.55
Capacity Current 5hr 1.48
Capacity Current 1hr 5.92
Max Continuous Discharge Current (A) 117.0
Internal Resistance (mΩ) 20.0
Capacity Current 20hr 0.425
Short Circuit Current (A) 238.0
Nominal Power W/Cell 15 min 37.3
Recommended Chargers PSC-12500ACX
Nominal Power W/Cell 15min Voltage 10.0

Constant Current Discharge Table:
VoltageOverTime5min10min15min20min30min45min1h1.5h2h3h4h5h6h8h10h20h
1.60V/cell40.926.319.915.710.87.35.924.053.162.261.791.521.31.020.820.438
1.65V/cell37.925.019.215.210.67.175.823.983.122.231.771.491.281.00.8120.434
1.67V/cell37.624.819.115.110.57.115.783.963.12.221.761.491.281.00.8070.432
1.70V/cell36.124.218.714.810.37.035.723.933.072.21.741.481.270.9930.8010.429
1.75V/cell33.623.118.014.410.16.95.623.863.022.171.721.461.250.9810.7920.425
1.80V/cell31.122.017.414.09.886.765.523.82.972.141.71.441.230.9690.7820.421
1.85V/cell28.721.016.713.69.646.635.423.742.932.11.671.421.220.9570.7730.416
Expand
Constant Power Discharge Table:
VoltageOverTime5min10min15min20min30min45min1h1.5h2h3h4h5h6h8h10h20h
1.60V/cell75.349.037.329.520.513.911.37.796.14.43.52.982.552.011.620.876
1.65V/cell70.547.036.328.820.213.711.27.716.034.353.462.952.521.991.60.867
1.67V/cell69.846.636.028.620.013.611.17.666.04.333.442.932.511.981.60.864
1.70V/cell67.345.535.328.219.713.511.07.65.964.33.422.912.491.961.590.858
1.75V/cell63.043.734.327.519.413.310.97.55.884.243.382.882.471.941.570.85
1.80V/cell58.741.933.326.819.013.110.77.45.814.193.342.852.441.921.550.841
1.85V/cell54.540.132.226.118.612.910.57.35.734.143.32.812.411.91.540.832
Expand

Charge Voltage (25C) - Cycle Use : 2.35V-2.40V/cell -5mV/cell/℃

Charge Voltage (25C) - Float Charge : 2.25V-2.30V/cell -3mV/cell/℃

Recommended Charge Current (C rate) : 0.1 C-0.3C

Image Featured
PSH-1280
Case Material ABS (UL94 HB or V-0 optional)
Minimum Weight (kg) 2.4
Minimum Weight (lbs) 5.291
Length (in) 5.945
Length (mm) 151.0
Width (in) 2.559
Dimensions Image
PSH-1280
Width (mm) 65.0
Height (in) 3.701
Height (mm) 94.0
Height Over Terminal (in) 3.937
Height Over Terminal (mm) 100.0

CE
CE

Indicates that a product has been assessed by the manufacturer and deemed to meet EU safety, health and environmental protection requirements

Conflict Minerals

Conflict mineral reporting using industry standard template

Extended Minerals

Extended mineral reporting using industry standard template

IEC60896
IEC60896

Compliant with IEC standard applying to all stationary lead-acid cells and monobloc batteries of the valve regulated type for float charge applications

ISO9001:2015
ISO9001:2015

International standard that specifies requirements for a quality management system (QMS)

PFAS

PFAS (Per- and polyfluoroalkyl substances) Regulatory Compliance

Prop65
Prop65

Compliance required providing warnings to Californians about significant exposures to chemicals that cause cancer, birth defects, or other reproductive harm

REACH

Registration, Evaluation, Authorization, and Restriction of Chemicals (REACH) Annex XVII

RoHS

European Union's Restriction of Hazardous Substances (RoHS) Directive (EU 2011/65/EU)

SLA Transport
SLA Transport

Power-Sonic sealed lead acid batteries are classified as UN2800 non-spillable batteries and comply with all applicable transportation regulations. These batteries have been tested and certified to meet IMDG Special Provisions SP238.1 and SP238.2, and IATA Special Provision A67, making them excepted from most hazardous materials requirements when terminals are protected from short circuit. Approved for transport by air, ground, and sea under DOT, IATA, and IMDG regulations.

SVHC

Substances of Very High Concern Regulations

TSCA

US Environmental Protection Agency Toxic Substances Control Act (US EPA TSCA)

UL 1989

These requirements cover valve regulated or vented batteries that can be used as instrument batteries, enclosed batteries, emergency lighting and power batteries and uninterruptible power supply batteries

Characteristic 1200803407 S1200802109005
Terminal Type F2 F2
VdS n n
Active on Web US y n
Active on Web EMEA y n
Terminal Image 1200803407 S1200802109005
SKU Battery PSH-1280 FR F2 PSH-1280 FR F2
  • PSH-1280 FR F2
  • PSH-1280 FR F2

Features and Documents

AGM Technology

Absorbent Glass Mat (AGM) technology for superior performance, service life, and reliability

High-Rate UPS Application

Superb high-rate discharge characteristics that ensure reliable, on demand performance in UPS applications

Power Volume Ratio

Excellent power to volume ratio yielding high energy density

SLA ABS Case

Rugged vibration and impact resistant ABS case and cover

SLA Maintenance Free

Proven valve regulated technology that guarantees safe operation without maintenance or refilling

Graphs

Capacity Retention SLA

Capacity Retention SLA

Shelf life of SLA at various temperatures

PHR Cycle Life

PHR Cycle Life

Cycle life vs depth of discharge for the PHR series

SLA Charging

SLA Charging

Charging characteristics for SLA

SLA Float Life 5YR

SLA Float Life 5YR

5 year float life vs. temperature for SLA

Join Us in Powering the Future

Interested in Our Products?

Speak with our experts to find the best batteries, chargers, or
energy storage solutions for your specific application.

FAQs About Battery and
Energy Solutions

Find answers to the most common questions about our energy solutions, including compliance, customization, and delivery options.

Yes, our batteries are engineered for universal fit with most major OEM fire, security, and access control panels for easy installation.

y delivering dependable backup and energy storage solutions, our products support continuous operation for critical automation, helping prevent downtime caused by power loss or disruptions.

Most Power-Sonic industrial batteries are maintenance-free, minimizing routine service while maximizing uptime and reducing total cost of ownership for busy operations.